Hello, Welcome To Fuan Feili Motor Co.,Ltd.

                  Online
Contact Us

+8618033991889

News

news
Contact Us

+8618033991889

How do I start the diesel generator? How to stop the diesel generator?

分类: Company News Release time:21-01-20 Page view:426

.
~Manual Start

1. Manual start of diesel generator: after testing the normal alarm system, the generator can start by itself after the control switch is focused on the manual (MAN) position.  

2, diesel generator STOP: the control switch to STOP position or press the red emergency STOP button to STOP the operation of the generator.  In case of emergency, the emergency stop button can be pressed directly  

Forced outage.  If the red emergency stop button must be pressed back to the original position, otherwise the generator will not start.

~Automatic switching control

1, the control switch to AUTO, and with the power supply automatic switch (ATS) control switch must also be placed in the automatic position, when the mains stop, A·T·S will start the letter  

Give the generator control system, the generator will start automatically.  

2, when the control switch concerns to STOP (STOP), or still in automatic, but the mains has been restored when the ATS will send STOP signal, the generator will automatically STOP.  Note: Generator in operation,  

When automatic shutdown occurs due to fault (over speed, high water temperature, low oil pressure, etc.), the fault recovery button must be pressed down after troubleshooting to prepare for restart.  

Points to note in operation of diesel generator – Fu ‘an Feili Motor Co., LTD  

1. AC ammeter: needle indicator is normal, switch the current switch, measure the phase current value between each phase sequence, the phase sequence difference should not exceed 10%.  

2. AC voltmeter: the voltage indicated by the meter needle is normal.  

3. Whether the oil pressure indicated by the oil pressure gauge is in the normal range.  

4. Charging meter: Whether the pointer is in the direction of (+).  

5. Whether the water temperature indicated by the water thermometer is in the normal range of 65 ° C to 95 ° C.  

6. Tachometer: Is the revolution of the engine appropriate?  (60Hz at 1800 RPM)  

7. Whether the generator engine has abnormal sound or vibration.